{"title":"Double Glass Bifacial","description":null,"products":[{"product_id":"aik-a-mah60-510-ab-dg-g2","title":"AIKO 510W Neostar 2S+ N-Type Dual-Glass ABC All Black Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe AIKO Neostar 2S+ 510 W is an N-Type ABC (All Back Contact) solar panel\u003c\/strong\u003e. AIKO's All-Back-Contact cell design moves every busbar to the rear of the cell, leaving the entire front face free to collect light. It delivers \u003cstrong\u003e23.0 % module efficiency\u003c\/strong\u003e from a 1,954 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the AIKO Neostar 2S+ range\u003c\/h3\u003e\u003cp\u003eNeostar is AIKO's residential and light-commercial range, built around the same ABC cell in a smaller format with a black frame, so it suits domestic roofs where appearance matters as much as yield.\u003c\/p\u003e\u003cp\u003eAt 1,954 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. The black frame and dark cells keep the array visually quiet on a front-facing roof.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.26 %\/°C power temperature coefficient\u003c\/strong\u003e — the array keeps more of its rated output on hot days, when a UK roof can sit far above the 25 °C the nameplate figure is measured at.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCell-level shade optimisation\u003c\/strong\u003e — the ABC cell structure recovers output around chimneys, vents and pole shadows without adding a separate optimiser to every module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass-glass construction\u003c\/strong\u003e — dual glass, 2.0 + 2.0 mm coated semi-tempered front and back instead of a polymer backsheet, for better resistance to moisture ingress and micro-cracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHail tested to 25 mm at 23 m\/s\u003c\/strong\u003e — relevant for exposed and upland UK sites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-dated warranty\u003c\/strong\u003e — 30-year linear performance warranty; first-year degradation ≤1 %, ≤0.35 % per year from year 2 to 30.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e510 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e23.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e45.22 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e38.10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.39 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-Type ABC (All Back Contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass\u003c\/td\u003e\n\u003ctd\u003eDual glass, 2.0 + 2.0 mm coated semi-tempered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eBlack anodised aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,954 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e27.2 kg ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL), ±1,200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.26 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.22 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.05 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHail test\u003c\/td\u003e\n\u003ctd\u003e25 mm hail at 23 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire rating\u003c\/td\u003e\n\u003ctd\u003eIEC Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty and certification\u003c\/h3\u003e\u003cp\u003e30-year linear performance warranty; first-year degradation ≤1 %, ≤0.35 % per year from year 2 to 30.\u003c\/p\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.22 m². A 4 kWp array needs 8 of them (4.08 kWp over about 18 m²). A 6 kWp array needs 12 of them (6.12 kWp over about 27 m²). At 27.2 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout AIKO\u003c\/h3\u003e\u003cp\u003eAIKO Solar builds every module in its range on ABC (All Back Contact) cells, a structure it developed to move the cell's contacts out of the light path entirely. The design has taken an Intersolar Award and a Red Dot design award, and it is what puts AIKO modules at the top of the mainstream efficiency tables.\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=ZFFfJfWSCcs\" target=\"_blank\" rel=\"noopener\"\u003eAIKO ABC Core Technologies\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=sDMGgAHkAoc\" target=\"_blank\" rel=\"noopener\"\u003eABC Module Test - Partial Shading Optimisation Function\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3Z6V_2Q1AAs\" target=\"_blank\" rel=\"noopener\"\u003eABC Module Test - High Temperature Restriction Test\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=zy4DoXfTEhY\" target=\"_blank\" rel=\"noopener\"\u003eAIKO Fabrik\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the AIKO Neostar 2S+ are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"AIKO","offers":[{"title":"Default Title","offer_id":57440503824716,"sku":"AIK-A-MAH60-510-AB-DG-G2","price":73.69,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/AIK-A-MAH60-510-AB-DG-G2.jpg?v=1784590664"},{"product_id":"dm-585m10t-b72hsw","title":"DMEGC Solar 585W N-Type Bifacial Double Glass Silver Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe DMEGC Solar DMEGC Infinity is an N-type TOPCon solar panel\u003c\/strong\u003e. TOPCon cells add a passivated contact layer behind the silicon, cutting the recombination losses that limit older PERC modules. It delivers \u003cstrong\u003e22.6 % module efficiency\u003c\/strong\u003e from a 2,278 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the DMEGC Infinity range\u003c\/h3\u003e\u003cp\u003eDMEGC's Infinity range is a large-format bifacial TOPCon module for commercial rooftop and ground-mount arrays.\u003c\/p\u003e\u003cp\u003eAt 2,278 mm tall and 2.58 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.29 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±5 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 585 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e585 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.6 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e52.70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e44.04 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower at BNPI\u003c\/td\u003e\n\u003ctd\u003e647 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono-crystalline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e144 (6 × 24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront cover\u003c\/td\u003e\n\u003ctd\u003e2 mm heat-strengthened glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,278 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e31.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003e3 diodes, IP68 to IEC 62790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003ePV-ZH202B \/ MC4-EVO 2 A (1500 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.29 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.25 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.048 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal module operating temperature\u003c\/td\u003e\n\u003ctd\u003e42 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum test load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum design load\u003c\/td\u003e\n\u003ctd\u003e3,600 Pa front \/ 1,600 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.58 m². A 4 kWp array needs 7 of them (4.09 kWp over about 18 m²). A 6 kWp array needs 10 of them (5.85 kWp over about 26 m²). At 31.8 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout DMEGC Solar\u003c\/h3\u003e\u003cp\u003eDMEGC Solar is the photovoltaic arm of the Hengdian Group, with its European operation based in the Netherlands. Its n-type TOPCon modules are built to EN 50380.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the DMEGC Solar DMEGC Infinity are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"DMEGC Solar","offers":[{"title":"Default Title","offer_id":57440556319052,"sku":"DM-585M10T-B72HSW","price":65.08,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/DM-585M10T-B72HSW.jpg?v=1784590818"},{"product_id":"jam54d-40-455-lb-tslc-mc4","title":"JA Solar 455W N-Type Double Glass Bifacial Traceable Low Carbon Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM54D40 LB 455 W is an N-type mono, 16BB solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.8 % module efficiency\u003c\/strong\u003e from a 1,762 × 1,134 mm frame.\u003c\/p\u003e\n\u003cdiv class=\"warning\"\u003eThis product must be installed by a qualified electrician\/technician. All installations must adhere to local wiring regulations and standards. ClearRay Solar will not be held liable for any product malfunctions as a result of incorrectly installed systems.\u003c\/div\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,762 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.300 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +5 W power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 455 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e455 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.8 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e39.50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e33.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.56 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.79 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e491 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono, 16BB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm \/ 1.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,762 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.300 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.260 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.046 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.00 m². A 4 kWp array needs 9 of them (4.09 kWp over about 18 m²). A 6 kWp array needs 13 of them (5.92 kWp over about 26 m²). Each module weighs 22.0 kg.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM54D40 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440803520844,"sku":"JAM54D-40-455-LB-TSLC-MC4","price":59.82,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM54D-40-455-LB-TSLC-MC4.jpg?v=1784621342"},{"product_id":"jam54d-40-460-lb-tslc-mc4","title":"JA Solar 460W N-Type Double Glass Bifacial Traceable Low Carbon Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM54D40 LB 460 W is an N-type Bycium+ bifacial double glass solar panel\u003c\/strong\u003e. JA Solar's n-type Bycium+ cells use a passivated contact structure that lifts efficiency and lowers first-year degradation against p-type PERC. It delivers \u003cstrong\u003e23.0 % module efficiency\u003c\/strong\u003e from a 1,762 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,762 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-dated warranty\u003c\/strong\u003e — 25-year product warranty and 30-year linear performance warranty; 1 % first-year degradation, 0.4 % per year over 30 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 460 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e460 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e23.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e39.70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e33.17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.64 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.87 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e497 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono (Bycium+, 16BB half-cell)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm \/ 1.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,762 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1,762 ±2 mm X 1,134 ±2 mm X 30 ±1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 38 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty and certification\u003c\/h3\u003e\u003cp\u003e25-year product warranty and 30-year linear performance warranty; 1 % first-year degradation, 0.4 % per year over 30 years. Certified to IEC 61215, IEC 61730, UL 61215, UL 61730, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, IEC 62941:2019.\u003c\/p\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.00 m². A 4 kWp array needs 9 of them (4.14 kWp over about 18 m²). A 6 kWp array needs 13 of them (5.98 kWp over about 26 m²). Each module weighs 22.0 kg.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM54D40 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440803717452,"sku":"JAM54D-40-460-LB-TSLC-MC4","price":61.73,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM54D-40-460-LB-TSLC-MC4.jpg?v=1784621346"},{"product_id":"jam54d-40-460-lb-ts-mc4","title":"JA Solar 460W N-Type Double Glass Bifacial Traceable Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM54D40 LB 460 W is an N-type Bycium+ bifacial double glass solar panel\u003c\/strong\u003e. JA Solar's n-type Bycium+ cells use a passivated contact structure that lifts efficiency and lowers first-year degradation against p-type PERC. It delivers \u003cstrong\u003e23.0 % module efficiency\u003c\/strong\u003e from a 1,762 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,762 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-dated warranty\u003c\/strong\u003e — 25-year product warranty and 30-year linear performance warranty; 1 % first-year degradation, 0.4 % per year over 30 years.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 460 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e460 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e23.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e39.70 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e33.17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.64 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.87 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e497 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono (Bycium+, 16BB half-cell)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm \/ 1.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,762 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1,762 ±2 mm X 1,134 ±2 mm X 30 ±1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 38 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty and certification\u003c\/h3\u003e\u003cp\u003e25-year product warranty and 30-year linear performance warranty; 1 % first-year degradation, 0.4 % per year over 30 years. Certified to IEC 61215, IEC 61730, UL 61215, UL 61730, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, IEC 62941:2019.\u003c\/p\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.00 m². A 4 kWp array needs 9 of them (4.14 kWp over about 18 m²). A 6 kWp array needs 13 of them (5.98 kWp over about 26 m²). Each module weighs 22.0 kg.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM54D40 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440803815756,"sku":"JAM54D-40-460-LB-TS-MC4","price":61.73,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM54D-40-460-LB-TS-MC4.jpg?v=1784621347"},{"product_id":"jam54d-40-465-lb-ts-mc4","title":"JA Solar 465W N-Type Double Glass Bifacial Traceable Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM54D40 LB 465 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e23.3 % module efficiency\u003c\/strong\u003e from a 1,762 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,762 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±5 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 465 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e465 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e23.3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e40.20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e33.50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.88 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower at BNPI\u003c\/td\u003e\n\u003ctd\u003e513 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm, anti-reflective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm, heat-strengthened\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eAnodised aluminium alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,762 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e21.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 38 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.00 m². A 4 kWp array needs 9 of them (4.18 kWp over about 18 m²). A 6 kWp array needs 13 of them (6.04 kWp over about 26 m²). Each module weighs 21.4 kg.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM54D40 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440804077900,"sku":"JAM54D-40-465-LB-TS-MC4","price":63.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM54D-40-465-LB-TS-MC4.jpg?v=1784621349"},{"product_id":"jam54d-41-450-lb-ts-ab-mc4","title":"JA Solar 450W N-Type Double Glass Bifacial Traceable All Black Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM54D41 LB 450 W is an N-type mono, 16BB solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.5 % module efficiency\u003c\/strong\u003e from a 1,762 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\n\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\n\u003cp\u003eAt 1,762 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. The black frame and dark cells keep the array visually quiet on a front-facing roof. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small. \u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.300 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +5 W power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 450 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e39.30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e32.82 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.48 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e486 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono, 16BB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm \/ 1.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,762 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.300 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.260 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.046 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\n\u003cp\u003eEach panel covers 2.00 m². A 4 kWp array needs 9 of them (4.05 kWp over about 18 m²). A 6 kWp array needs 13 of them (5.85 kWp over about 26 m²). Each module weighs 22.0 kg.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\n\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM54D41 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440804471116,"sku":"JAM54D-41-450-LB-TS-AB-MC4","price":60.63,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JA_Solar_450W_N-Type_Double_Glass_Bifacial_All_Black_Solar_Panel.jpg?v=1790990105"},{"product_id":"jam54d-41-450-lb-ts-ht-ab-mc4","title":"JA Solar 450W N-Type Double Glass Bifacial Traceable Hail Resistance Class 4 All Black Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM54D41 LB 450 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.5 % module efficiency\u003c\/strong\u003e from a 1,762 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,762 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. The black frame and dark cells keep the array visually quiet on a front-facing roof. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHail tested: Hail Resistance Class 4 (HW4)\u003c\/strong\u003e — relevant for exposed and upland UK sites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReinforced load rating, 8,000 Pa front \/ 5,000 Pa back\u003c\/strong\u003e — for high-snow and high-wind locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 450 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e40.30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e32.99 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.41 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.64 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e486 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.8 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,762 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e8,000 Pa front \/ 5,000 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHail class\u003c\/td\u003e\n\u003ctd\u003eHail Resistance Class 4 (HW4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eClass C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.00 m². A 4 kWp array needs 9 of them (4.05 kWp over about 18 m²). A 6 kWp array needs 13 of them (5.85 kWp over about 26 m²). At 28.0 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM54D41 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440804602188,"sku":"JAM54D-41-450-LB-TS-HT-AB-MC4","price":59.26,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM54D-41-450-LB-TS-HT-AB-MC4.jpg?v=1784621354"},{"product_id":"jam54d-41-455-lb-ts-ab-mc4","title":"JA Solar 455W N-Type Double Glass Bifacial Traceable All Black Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM54D41 LB 455 W is an N-type mono, 16BB solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.8 % module efficiency\u003c\/strong\u003e from a 1,762 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,762 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. The black frame and dark cells keep the array visually quiet on a front-facing roof. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.300 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +5 W power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 455 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e455 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.8 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e39.50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e33.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.56 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.79 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e491 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono, 16BB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm \/ 1.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,762 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.300 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.260 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.046 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.00 m². A 4 kWp array needs 9 of them (4.09 kWp over about 18 m²). A 6 kWp array needs 13 of them (5.92 kWp over about 26 m²). Each module weighs 22.0 kg.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM54D41 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440805060940,"sku":"JAM54D-41-455-LB-TS-AB-MC4","price":61.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM54D-41-455-LB-TS-AB-MC4.jpg?v=1784621356"},{"product_id":"jam60d-41-500-lb-ts-ab-mc4","title":"JA Solar 500W N-Type TOPCon Traceable Double Glass Bifacial All Black Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM60D41 LB 500 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.6 % module efficiency\u003c\/strong\u003e from a 1,953 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,953 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. The black frame and dark cells keep the array visually quiet on a front-facing roof. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 500 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.6 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e45.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e38.26 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.07 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower at BNPI\u003c\/td\u003e\n\u003ctd\u003e552 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm, anti-reflective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm, heat-strengthened\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eAnodised aluminium alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,953 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e27.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.21 m². A 4 kWp array needs 8 of them (4.00 kWp over about 18 m²). A 6 kWp array needs 12 of them (6.00 kWp over about 27 m²). At 27.3 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM60D41 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440805355852,"sku":"JAM60D-41-500-LB-TS-AB-MC4","price":69.39,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM60D-41-500-LB-TS-AB-MC4.jpg?v=1784621360"},{"product_id":"jam60d-41-505-lb-ts-ab-mc4","title":"JA Solar 505W N-Type TOPCon Traceable Double Glass Bifacial All Black Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM60D41 LB 505 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.8 % module efficiency\u003c\/strong\u003e from a 1,953 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,953 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. The black frame and dark cells keep the array visually quiet on a front-facing roof. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 505 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e505 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.8 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e45.20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e38.43 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower at BNPI\u003c\/td\u003e\n\u003ctd\u003e557 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm, anti-reflective coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm, heat-strengthened\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eAnodised aluminium alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,953 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e27.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.21 m². A 4 kWp array needs 8 of them (4.04 kWp over about 18 m²). A 6 kWp array needs 12 of them (6.06 kWp over about 27 m²). At 27.3 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM60D41 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440805454156,"sku":"JAM60D-41-505-LB-TS-AB-MC4","price":71.3,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM60D-41-505-LB-TS-AB-MC4.jpg?v=1784621362"},{"product_id":"jam60d-42-530-lb-bf","title":"JA Solar 530W N-Type TOPCon Double Glass Bifacial Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM60D42 LB 530 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.7 % module efficiency\u003c\/strong\u003e from a 2,063 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,063 mm tall and 2.34 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 530 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e530 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.7 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e43.93 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e36.81 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e15.26 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e14.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e572 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,063 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.34 m². A 4 kWp array needs 8 of them (4.24 kWp over about 19 m²). A 6 kWp array needs 11 of them (5.83 kWp over about 26 m²). At 28.8 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/XqyQshAzrUw?si=jZPkFMHIuBSJs_bF\" target=\"_blank\" rel=\"noopener\"\u003eWatch the D42 module series in this video→\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM60D42 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440805552460,"sku":"JAM60D-42-530-LB-BF","price":67.47,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM60D-42-530-LB-BF.jpg?v=1784621363"},{"product_id":"jam60d-42-530-lb-ts-bf","title":"JA Solar 530W N-Type TOPCon Traceable Double Glass Bifacial Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM60D42 LB 530 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.7 % module efficiency\u003c\/strong\u003e from a 2,063 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,063 mm tall and 2.34 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 530 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e530 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.7 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e43.93 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e36.81 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e15.26 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e14.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e572 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,063 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.34 m². A 4 kWp array needs 8 of them (4.24 kWp over about 19 m²). A 6 kWp array needs 11 of them (5.83 kWp over about 26 m²). At 28.8 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/XqyQshAzrUw?si=jZPkFMHIuBSJs_bF\" target=\"_blank\" rel=\"noopener\"\u003eWatch the D42 module series in this video→\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM60D42 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440805716300,"sku":"JAM60D-42-530-LB-TS-BF","price":67.47,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM60D-42-530-LB-TS-BF.jpg?v=1784621363"},{"product_id":"jam60d-42-530-lb-tslc-bf","title":"JA Solar 530W N-Type TOPCon Traceable Low Carbon Double Glass Bifacial Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM60D42 LB 530 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.7 % module efficiency\u003c\/strong\u003e from a 2,063 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,063 mm tall and 2.34 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±5 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 530 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e530 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.7 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e43.93 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e36.81 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e15.26 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e14.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e572 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,063 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.34 m². A 4 kWp array needs 8 of them (4.24 kWp over about 19 m²). A 6 kWp array needs 11 of them (5.83 kWp over about 26 m²). At 28.8 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/XqyQshAzrUw?si=jZPkFMHIuBSJs_bF\" target=\"_blank\" rel=\"noopener\"\u003eWatch the D42 module series in this video→\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM60D42 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440806142284,"sku":"JAM60D-42-530-LB-TSLC-BF","price":67.47,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM60D-42-530-LB-TSLC-BF.jpg?v=1784621366"},{"product_id":"jam60d-42-535-lb-ts-bf","title":"JA Solar 535W N-Type TOPCon Traceable Double Glass Bifacial Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM60D42 LB 535 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.9 % module efficiency\u003c\/strong\u003e from a 2,063 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,063 mm tall and 2.34 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±5 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 535 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e535 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e44.13 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e37.03 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e15.31 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e14.45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e578 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,063 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.34 m². A 4 kWp array needs 7 of them (3.75 kWp over about 16 m²). A 6 kWp array needs 11 of them (5.88 kWp over about 26 m²). At 28.8 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/XqyQshAzrUw?si=jZPkFMHIuBSJs_bF\" target=\"_blank\" rel=\"noopener\"\u003eWatch the D42 module series in this video→\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM60D42 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440806371660,"sku":"JAM60D-42-535-LB-TS-BF","price":69.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM60D-42-535-LB-TS-BF.jpg?v=1784621366"},{"product_id":"jam60d-42-535-lb-tslc-bf","title":"JA Solar 535W N-Type TOPCon Traceable Low Carbon Double Glass Bifacial Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM60D42 LB 535 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.9 % module efficiency\u003c\/strong\u003e from a 2,063 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,063 mm tall and 2.34 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±5 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 535 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e535 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e44.13 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e37.03 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e15.31 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e14.45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e578 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,063 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.34 m². A 4 kWp array needs 7 of them (3.75 kWp over about 16 m²). A 6 kWp array needs 11 of them (5.88 kWp over about 26 m²). At 28.8 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/XqyQshAzrUw?si=jZPkFMHIuBSJs_bF\" target=\"_blank\" rel=\"noopener\"\u003eWatch the D42 module series in this video→\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM60D42 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440806502732,"sku":"JAM60D-42-535-LB-TSLC-BF","price":69.86,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM60D-42-535-LB-TSLC-BF.jpg?v=1784621368"},{"product_id":"jam60d-42-540-lb-ts-bf","title":"JA Solar 540W N-Type TOPCon Traceable Double Glass Bifacial Black Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM60D42 LB 540 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e23.1 % module efficiency\u003c\/strong\u003e from a 2,063 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,063 mm tall and 2.34 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 540 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e23.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e44.33 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e37.25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e15.36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e14.50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e583 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e120 (6 × 20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,063 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.34 m². A 4 kWp array needs 7 of them (3.78 kWp over about 16 m²). A 6 kWp array needs 11 of them (5.94 kWp over about 26 m²). At 28.8 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/XqyQshAzrUw?si=jZPkFMHIuBSJs_bF\" target=\"_blank\" rel=\"noopener\"\u003eWatch the D42 module series in this video→\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM60D42 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440806633804,"sku":"JAM60D-42-540-LB-TS-BF","price":71.78,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JA_Solar_540W_2.webp?v=1789034583"},{"product_id":"jam72d-40-600-lb-ts-mc4","title":"JA Solar 600W N-Type TOPCon Traceable Double Glass Bifacial Silver Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM72D40 LB 600 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.7 % module efficiency\u003c\/strong\u003e from a 2,333 × 1,134 mm frame.\u003c\/p\u003e\n\u003cdiv class=\"warning\"\u003e Due to size of the panels and size of the gap between the slats of the pallets (both length and width entries) a fork lift truck on site is required to offload these modules. In Germany, this module may only be installed on building-independent solar systems in publicly inaccessible areas with a height of up to 3m.\u003c\/div\u003e\n\u003cdiv class=\"warning\"\u003e This product must be installed by a qualified electrician\/technician. All installations must adhere to local wiring regulations and standards. ClearRay Solar will not be held liable for any product malfunctions as a result of incorrectly installed systems.\u003c\/div\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,333 mm tall and 2.65 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±5 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 600 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e600 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.7 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e52.40 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e43.76 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.48 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.71 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e648 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e144 (6 × 24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,333 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e32.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.65 m². A 4 kWp array needs 7 of them (4.20 kWp over about 19 m²). A 6 kWp array needs 10 of them (6.00 kWp over about 26 m²). At 32.5 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM72D40 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440806830412,"sku":"JAM72D-40-600-LB-TS-MC4","price":72.25,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM72D-40-600-LB-TS-MC4.jpg?v=1784621371"},{"product_id":"jam72d-40-605-lb-ts-mc4","title":"JA Solar 605W N-Type TOPCon Traceable Double Glass Bifacial Silver Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM72D40 LB 605 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.9 % module efficiency\u003c\/strong\u003e from a 2,333 × 1,134 mm frame.\u003c\/p\u003e\n\u003cdiv class=\"warning\"\u003e Due to size of the panels and size of the gap between the slats of the pallets (both length and width entries) a fork lift truck on site is required to offload these modules. In Germany, this module may only be installed on building-independent solar systems in publicly inaccessible areas with a height of up to 3m.\u003c\/div\u003e\n\u003cdiv class=\"warning\"\u003e This product must be installed by a qualified electrician\/technician. All installations must adhere to local wiring regulations and standards. ClearRay Solar will not be held liable for any product malfunctions as a result of incorrectly installed systems.\u003c\/div\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,333 mm tall and 2.65 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±5 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 605 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e605 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e52.60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e43.94 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.53 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.77 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e653 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e144 (6 × 24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,333 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e32.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.65 m². A 4 kWp array needs 7 of them (4.24 kWp over about 19 m²). A 6 kWp array needs 10 of them (6.05 kWp over about 26 m²). At 32.5 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM72D40 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440809124172,"sku":"JAM72D-40-605-LB-TS-MC4","price":73.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM72D-40-605-LB-TS-MC4.jpg?v=1784621376"},{"product_id":"jam72d-40-610-lb-ts-mc4","title":"JA Solar 610W N-Type TOPCon Traceable Double Glass Bifacial Silver Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM72D40 LB 610 W is an N-type mono solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e23.1 % module efficiency\u003c\/strong\u003e from a 2,333 × 1,134 mm frame.\u003c\/p\u003e\n\u003cdiv class=\"warning\"\u003e Due to size of the panels and size of the gap between the slats of the pallets (both length and width entries) a fork lift truck on site is required to offload these modules. In Germany, this module may only be installed on building-independent solar systems in publicly inaccessible areas with a height of up to 3m.\u003c\/div\u003e\n\u003cdiv class=\"warning\"\u003e This product must be installed by a qualified electrician\/technician. All installations must adhere to local wiring regulations and standards. ClearRay Solar will not be held liable for any product malfunctions as a result of incorrectly installed systems.\u003c\/div\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 2,333 mm tall and 2.65 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.290 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±5 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +3 % power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 610 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e610 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e23.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e52.80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e44.11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.57 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.83 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e659 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e144 (6 × 24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e2.0 mm \/ 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e2,333 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e32.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.290 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.250 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.045 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 29 \/ Class C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.65 m². A 4 kWp array needs 7 of them (4.27 kWp over about 19 m²). A 6 kWp array needs 10 of them (6.10 kWp over about 26 m²). At 32.5 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM72D40 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":57440809353548,"sku":"JAM72D-40-610-LB-TS-MC4","price":76.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM72D-40-610-LB-TS-MC4.jpg?v=1784621376"},{"product_id":"lr7-72hvd-645m","title":"LONGi 645W Hi-MO X10 Double Glass Bifacial HPBC Silver Frame Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe LONGi Hi-MO X10 645 W is a Back-contact (BC) cell on an N-type TaiRay wafer solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e23.9 % module efficiency\u003c\/strong\u003e from a 2,382 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the LONGi Hi-MO X10 range\u003c\/h3\u003e\u003cp\u003eHi-MO X10 is LONGi's high-end residential platform. LONGi rates the HPBC 2.0 cell for higher generation from the same area, a gridline-free low-glare face, and an anti-shading function that limits localised overheating where part of the array is shaded.\u003c\/p\u003e\u003cp\u003eAt 2,382 mm tall and 2.70 m² this is a commercial-format module, intended for warehouse and barn roofs, ground mounts and solar farms where the extra length is not a constraint. It is usually too long for a typical domestic roof plane.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass-glass construction\u003c\/strong\u003e — dual glass, 2.0+2.0 mm semi-tempered glass front and back instead of a polymer backsheet, for better resistance to moisture ingress and micro-cracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHail tested to 25 mm at 23 m\/s\u003c\/strong\u003e — relevant for exposed and upland UK sites.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-dated warranty\u003c\/strong\u003e — 15-year warranty for materials and processing and a 30-year linear power output warranty; first-year degradation under 1 %, 0.35 % per year from year 2 to 30.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e645 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e23.9 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e54.12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e44.77 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e15.06 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e14.41 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V (IEC\/UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e144 (6 × 24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass\u003c\/td\u003e\n\u003ctd\u003eDual glass, 2.0+2.0 mm semi-tempered glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminium alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2,382 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e33.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal operating cell temperature\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHail test\u003c\/td\u003e\n\u003ctd\u003e25 mm Hailstone at the speed of 23m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire rating\u003c\/td\u003e\n\u003ctd\u003eUL type 29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWarranty and certification\u003c\/h3\u003e\u003cp\u003e15-year warranty for materials and processing and a 30-year linear power output warranty; first-year degradation under 1 %, 0.35 % per year from year 2 to 30. Certified to IEC 61215, IEC 61730, UL 61730, ISO 9001:2015, ISO 14001:2015, ISO 45001:2018 and IEC 62941.\u003c\/p\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.70 m². A 4 kWp array needs 6 of them (3.87 kWp over about 16 m²). A 6 kWp array needs 9 of them (5.80 kWp over about 24 m²). At 33.5 kg each they are a two-person lift.\u003c\/p\u003e\n\u003ch3\u003eAbout LONGi\u003c\/h3\u003e\u003cp\u003eLONGi is one of the largest solar manufacturers in the world and the company behind the Hi-MO series. Its HPBC back-contact platform is the successor to the PERC modules it shipped in volume for a decade, and it is manufactured to IEC 61215 and IEC 61730 under ISO 9001, ISO 14001, ISO 45001 and IEC 62941 quality systems.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the LONGi Hi-MO X10 are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"Longi","offers":[{"title":"Default Title","offer_id":57440840024396,"sku":"LR7-72HVD-645M","price":83.73,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/LR7-72HVD-645M.jpg?v=1784621693"},{"product_id":"jam54d-41-445-lb-tslc-ab-mc4","title":"JA Solar 445W N-Type Double Glass Bifacial Traceable Low Carbon All Black Solar Panel","description":"\u003cp\u003e\u003cstrong\u003eThe JA Solar JAM54D41 LB 445 W is an N-type mono, 16BB solar panel\u003c\/strong\u003e. It delivers \u003cstrong\u003e22.3 % module efficiency\u003c\/strong\u003e from a 1,762 × 1,134 mm frame.\u003c\/p\u003e\n\u003ch3\u003eAbout the JA Solar Deep Blue 4.0 Pro range\u003c\/h3\u003e\u003cp\u003eDeep Blue 4.0 Pro is JA Solar's n-type platform, using Bycium+ cells with a better temperature coefficient, lower light-induced degradation and improved low-light behaviour than the p-type modules it replaces.\u003c\/p\u003e\u003cp\u003eAt 1,762 × 1,134 mm it is a residential-format module, sized to fit the rafter spans and roof planes of a standard UK house. The black frame and dark cells keep the array visually quiet on a front-facing roof. Being bifacial, it earns most of its extra yield on flat roofs, ground mounts and light-coloured surfaces, where light reaches the back of the module; on a pitched tiled roof the rear-side gain is small.\u003c\/p\u003e\n\u003ch3\u003eWhy installers specify this panel\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e−0.300 %\/°C power temperature coefficient\u003c\/strong\u003e — output falls away more slowly as the modules heat up through the middle of the day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBifacial, 80 % ±10 %\u003c\/strong\u003e — the rear face adds generation from reflected and diffuse light, which suits flat roofs, ground mounts and light-coloured surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-black appearance\u003c\/strong\u003e — a black anodised frame and dark cells, for domestic roofs where the array has to be discreet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0 to +5 W power tolerance\u003c\/strong\u003e — every module is sorted to meet or beat its 445 W nameplate rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical characteristics (STC)\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (Pmax)\u003c\/td\u003e\n\u003ctd\u003e445 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule efficiency\u003c\/td\u003e\n\u003ctd\u003e22.3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e39.10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage at maximum power (Vmp)\u003c\/td\u003e\n\u003ctd\u003e32.65 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e14.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at maximum power (Imp)\u003c\/td\u003e\n\u003ctd\u003e13.63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower tolerance\u003c\/td\u003e\n\u003ctd\u003e0 to +5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower with 10% rear irradiance\u003c\/td\u003e\n\u003ctd\u003e481 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003eDC 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum series fuse rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003eSTC: AM1.5, 1,000 W\/m², 25 °C cell temperature.\u003c\/p\u003e\n\u003ch3\u003eMechanical specification\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell technology\u003c\/td\u003e\n\u003ctd\u003eN-type mono, 16BB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of cells\u003c\/td\u003e\n\u003ctd\u003e108 (6 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront \/ back glass\u003c\/td\u003e\n\u003ctd\u003e1.6 mm \/ 1.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e1,762 × 1,134 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction box\u003c\/td\u003e\n\u003ctd\u003eIP68, 3 bypass diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMC4-EVO2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e4 mm² (IEC), 12 AWG (UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTemperature and load ratings\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Pmax\u003c\/td\u003e\n\u003ctd\u003e−0.300 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Voc\u003c\/td\u003e\n\u003ctd\u003e−0.260 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient of Isc\u003c\/td\u003e\n\u003ctd\u003e+0.046 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e45 ±2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum static load\u003c\/td\u003e\n\u003ctd\u003e5,400 Pa front \/ 2,400 Pa back\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire performance\u003c\/td\u003e\n\u003ctd\u003eUL Type 38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eArray sizing\u003c\/h3\u003e\u003cp\u003eEach panel covers 2.00 m². A 4 kWp array needs 9 of them (4.00 kWp over about 18 m²). A 6 kWp array needs 13 of them (5.79 kWp over about 26 m²). Each module weighs 22.0 kg.\u003c\/p\u003e\n\u003ch3\u003eAbout JA Solar\u003c\/h3\u003e\u003cp\u003eJA Solar is one of the highest-volume module manufacturers in the industry. Its Deep Blue 4.0 Pro platform uses n-type Bycium+ cells with 16-busbar half-cell interconnection, and carries IEC 61215, IEC 61730, UL 61215 and UL 61730 certification alongside ISO 9001, ISO 14001, ISO 45001 and IEC 62941.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and warranty documents for the JA Solar JAM54D41 LB are in the Documents tab below. Buying for a project? Contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for pallet pricing.\u003c\/p\u003e","brand":"JA SOLAR","offers":[{"title":"Default Title","offer_id":58470382436684,"sku":"JAM54D-41-445-LB-TSLC-AB-MC4","price":55.12,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/JAM54D-41-445-LB-TSLC-AB-MC4.jpg?v=1787151430"}],"url":"https:\/\/clearraysolar.co.uk\/collections\/double-glass-bifacial.oembed","provider":"ClearRay Solar","version":"1.0","type":"link"}